Field Test of Cement
- When cement is thrown into the bucket of water it should float for sometime before sinking.
- If once hand is plunged into the bag of cement , it should feel cool.
- A thin paste of Portland cement with water should fill strictly between the fingers.
- Colour of cement should be greenish grey and should not show any visible lumps.
Laboratory Test of Cement
The laboratory test of cement are as follows :
- Fineness : As per I.S. surface area per gram of cement for ordinary Portland cement should not be less than 2250 sq.cm /gm . I.S. specifies that the maximum resider after sieving through a 90 micron I.S. sieve should be limited by weight for ordinary Portland cement.
- Initial setting time : Cement paste are initially in plastic state. Initial setting is that stage at which a crack that may appear will not reunite. This is not a sudden change, but it takes place gradually. Initial setting time of cement should not be less than 30 minute.
- Final setting time : This is the term which relates to the completion of the setting process. The setting time is influenced by the percentage of water, the temperature and the humidity of air. The setting time is controlled by adding a small quantity of gypsum in cement. Final setting time of cement is about 3 to 6 hours but it should be greater than 20 hours.
- Compressive Strength : Cement mortar cubes of surface area 50cm2 are prepared and kept wet for 3 days or 7 days. Then they are put in a compression testing machine.
- Soundness : Due to presence of lime and magnesium oxide, expansion of cement takes place when it comes in contact with water. Such expansion of cement is harmful and cement with less or no expansion is called sound cement. Expansion by le-chatlier apparatus should not be more than 10 mm.
No comments: